What was found
DURING CHECK-C MAINT IN THE AFT CARGO COMPT, CORROSION WAS FOUND UNDERSIDE RT FLOOR MEMBRANE AT STA 1117 TO 1136. INSTALLED NEW MEMBRANE PER DRAWING 9330612-23 AND SPM 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT IN THE AFT CARGO COMPT, CORROSION WAS FOUND UNDERSIDE RT FLOOR MEMBRANE AT STA 1117 TO 1136. INSTALLED NEW MEMBRANE PER DRAWING 9330612-23 AND SPM 6-70-01.