What was found
DURING CHECK-C MAINT FOUND CORRODED FLOOR SUPPORT AT RBL 44 INCHES, STA 160 TO 200. REMOVED CORRODED SUPPORT AND FABRICATED NEW SUPPORT. INSTALLED PER SRM 51-30-2. TREATED PER SRM 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND CORRODED FLOOR SUPPORT AT RBL 44 INCHES, STA 160 TO 200. REMOVED CORRODED SUPPORT AND FABRICATED NEW SUPPORT. INSTALLED PER SRM 51-30-2. TREATED PER SRM 51-10-3.