What was found
DURING CHECK-C MAINT FOUND CABIN FLOOR SUPPORT CORRODED AT STA 160 TO 200, RBL 52 INCHES. REPLACED FLOOR SUPPORT AT STA 160 TO 200 PER SPM 6-70-01. INSTALLED FASTENERS PER SRM 51-30-02 AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND CABIN FLOOR SUPPORT CORRODED AT STA 160 TO 200, RBL 52 INCHES. REPLACED FLOOR SUPPORT AT STA 160 TO 200 PER SPM 6-70-01. INSTALLED FASTENERS PER SRM 51-30-02 AND 51-30-5.