As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CHECK-C MAINT A CABIN FLOOR PANEL MOUNT HAD CORROSION ON AFT EDGE OF FLOOR PANEL MOUNT, STA 1174, FLOOR PANEL NUMBER 85. FABRICATED NEW FLOOR SUPPORT PER SPM 6-70-01. PRIMED AND PAINTED NEW SUPPORT PER SRM 51-10-03. INSTALLED NEW SUPPORT AND FASTENERS PER SRM 51-10-05.