What was found
DURING CHECK-C MAINT FOUND FLOOR SUPPORT CORRODED AT SEVERAL PLACES STA 1136 TO 1212, RBL 8 INCHES. INSTALLED NEW SUPPORT PER DRAWING 5936660. INSTALLED BOLTS, WASHERS AND NUTS PER SRM 51-30-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND FLOOR SUPPORT CORRODED AT SEVERAL PLACES STA 1136 TO 1212, RBL 8 INCHES. INSTALLED NEW SUPPORT PER DRAWING 5936660. INSTALLED BOLTS, WASHERS AND NUTS PER SRM 51-30-1.