What was found
DURING OP 15 MAINT CHECK FOUND STRAP REPAIR AT LONGERON 20L, AT STA 223. FABRICATED LONGERON SECTION FOR L20 FROM STA 200 TO 229 PER SPM 6-70-01, AND SRM 53-11-1 PAGE 25 AND 26. ORDERED NEW LONGERON CLIP AT STA 200 PER SRM 53-11-1 PAGE 25 AND 26. TREATED SURFACES PER SRM 51-10-3. INSTALLED PER SRM 51-30-5, SRM 51-60-0, AND SRM 51-20-2. SEALED PER SRM 51-20-0.