DURING CHECK-C MAINT FOUND FLOOR SUPPORT CORRODED AND BROKEN AT STA 180, RBL 9 IN TO RBL 44 INCHES. INSTALLED NEW FLOOR SUPPORT PER SPM 6-70-01 AND SRM 51-30.