What was found
DURING CHECK-C MAINT IN THE FWD CARGO COMPT FOUND CORROSION AT LONGERON 28R, FROM STA 349 TO 357. REPLACED LONGERON PER SRM 53-02, FIG 18. INSTALLED FASTENERS PER SRM 51-30-03. PRIMED AND PAINTED PER SRM 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT IN THE FWD CARGO COMPT FOUND CORROSION AT LONGERON 28R, FROM STA 349 TO 357. REPLACED LONGERON PER SRM 53-02, FIG 18. INSTALLED FASTENERS PER SRM 51-30-03. PRIMED AND PAINTED PER SRM 51-10-3.