What was found
DURING CHECK-C MAINT FOUND INTERCOSTAL CORRODED OTBD OF STA 1322, STRINGER 28L. FORMED NEW INTERCOSTAL PER SPM 6-70-01. INSTALLED PER SRM 51-30-5, 51-30-7, 51-10-4, AND 51-10-2A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND INTERCOSTAL CORRODED OTBD OF STA 1322, STRINGER 28L. FORMED NEW INTERCOSTAL PER SPM 6-70-01. INSTALLED PER SRM 51-30-5, 51-30-7, 51-10-4, AND 51-10-2A.