What was found
STL - DURING SPECIAL CHECK, FOUND A .25 INCH CRACK IN LONGERON 4L, AT BELTRING STATION. INSTALLED REPAIR PER SRM 53-02, FIGURE 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STL - DURING SPECIAL CHECK, FOUND A .25 INCH CRACK IN LONGERON 4L, AT BELTRING STATION. INSTALLED REPAIR PER SRM 53-02, FIGURE 2. (M)