What was found
STL - DURING OP-16, FOUND A 1 INCH CRACK IN OUTBOARD FLANGE OF LONGERON 3L, STATION 200. REMOVED DAMAGED LONGERON AND INSTALLED NEW ONE PER SRM 51-30-02 AND 53-30-5. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STL - DURING OP-16, FOUND A 1 INCH CRACK IN OUTBOARD FLANGE OF LONGERON 3L, STATION 200. REMOVED DAMAGED LONGERON AND INSTALLED NEW ONE PER SRM 51-30-02 AND 53-30-5. (M)