What was found
STL - DURING OP 15 MAINTENANCE CHECK, A CRACK WAS FOUND AT STA 200 LONGERON 4L. REPLACED LONGERON FROM STA 148 END FITTING TO FACTORY SPLICE PER SRM 51-10. ACFT TT: 70,351 HOURS. ACFT TC: 83,824. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STL - DURING OP 15 MAINTENANCE CHECK, A CRACK WAS FOUND AT STA 200 LONGERON 4L. REPLACED LONGERON FROM STA 148 END FITTING TO FACTORY SPLICE PER SRM 51-10. ACFT TT: 70,351 HOURS. ACFT TC: 83,824. (X)