What was found
MCI - DURING C-CHECK MAINTENANCE, CRACK INDICATIONS WERE FOUND USING EDDY CURRENT. THE CRACKS WERE IN THE FWD TWO FASTENERS/HOLES IN RIB CHORD UPPER VERT FLANGE STATION 759 LBL 70 WL 205, REPAIRED AS PER ARA 11617. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCI - DURING C-CHECK MAINTENANCE, CRACK INDICATIONS WERE FOUND USING EDDY CURRENT. THE CRACKS WERE IN THE FWD TWO FASTENERS/HOLES IN RIB CHORD UPPER VERT FLANGE STATION 759 LBL 70 WL 205, REPAIRED AS PER ARA 11617. (M)