MCI - DURING OP 16 MAINTENANCE CHECK, STRINGER SPLICE AT FS 434 S33L WAS FOUND CORRODED. REMOVED CORROSION PER SRM 51-10-00. REMOVED AND REPLACED STRINGER SPLICE AT STATION 434 33L PER SRM 51-10-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCI - DURING OP 16 MAINTENANCE CHECK, STRINGER SPLICE AT FS 434 S33L WAS FOUND CORRODED. REMOVED CORROSION PER SRM 51-10-00. REMOVED AND REPLACED STRINGER SPLICE AT STATION 434 33L PER SRM 51-10-00. (M)