What was found
MCI - DURING OP 16 MAINTENANCE CHECK, IN C-1 CARGO COMPT FS 434 STRINGER 38L, FOUND STRINGER SPLICE WITH HEAVY CORROSION. REMOVED CORROSION PER SRM 51-10-00. INSTALLED NEW STRINGER SPLICE PER SRM 53-30-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCI - DURING OP 16 MAINTENANCE CHECK, IN C-1 CARGO COMPT FS 434 STRINGER 38L, FOUND STRINGER SPLICE WITH HEAVY CORROSION. REMOVED CORROSION PER SRM 51-10-00. INSTALLED NEW STRINGER SPLICE PER SRM 53-30-03. (M)