What was found
MCI - DURING OP 16 MAINTENANCE CHECK, IN ELECTRONIC COMPT FOUND A DRILLED HOLE WITH A CRACK IN STRINGER 33L AT STATION 347. STOP DRILLED HOLE PER SRM 51-10-00. REPAIRED STRINGER PER SRM 53-00-03 FIG 203. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCI - DURING OP 16 MAINTENANCE CHECK, IN ELECTRONIC COMPT FOUND A DRILLED HOLE WITH A CRACK IN STRINGER 33L AT STATION 347. STOP DRILLED HOLE PER SRM 51-10-00. REPAIRED STRINGER PER SRM 53-00-03 FIG 203. (M)