What was found
MCI - DURING OP 16 MAINTENANCE CHECK, INNER GRANULAR CORROSION WAS FOUND AT INBD SIDE OF NR 2 CHAIR TRACK, FS 1267 - FS 1278. REPLACED NR 2 CHAIR TRACK FS 1220 - FS 1309 PER SRM 53-08. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCI - DURING OP 16 MAINTENANCE CHECK, INNER GRANULAR CORROSION WAS FOUND AT INBD SIDE OF NR 2 CHAIR TRACK, FS 1267 - FS 1278. REPLACED NR 2 CHAIR TRACK FS 1220 - FS 1309 PER SRM 53-08. (X)