What was found
MCI - DURING OP 16 MAINTENANCE CHECK, FOUND AFT FACE OF FORMER DOUBLER AT FS 937 CORRODED ABOVE L28L TO 29L. REMOVED CORROSION PER SRM 51-10-3. INSTALLED NEW DOUBLER PER SRM 51-01, PG 1 ITEM C. ACFT TT: 70,506 HOURS. ACFT TC: 66,322. (X)