What was found
MCI - DURING OVERNIGHT MAINTENANCE, FOUND LOWER ATTACH ANGLE FOR WRAP AROUND FAIRING AT VERTICAL STABILIZER CRACKED THROUGH FASTENER HOLE, 7 IN FORWARD OF PRODUCTION BREAK, LT SIDE FS 1421. REMOVED ATTACH ANGLE AND INSTALLED NEW ATTACH ANGLE PER SRM 51-10-0 AND TWA STD PRACTICES. CHECK-C 2-9-98 STL. ACFT TT: 33,526 HOURS. ACFT TC: 16,902. (X)