What was found
MCI - DURING OP15 MAINTENANCE CHECK, FOUND CABIN FLOOR MEMBRANE CRACKED BETWEEN STATION 579 AND 598, APPROX 58 INCH RBL, UNDER FWD END OF FLOOR PANEL 43. REPAIRED PER SRM 53-01, FIG 4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCI - DURING OP15 MAINTENANCE CHECK, FOUND CABIN FLOOR MEMBRANE CRACKED BETWEEN STATION 579 AND 598, APPROX 58 INCH RBL, UNDER FWD END OF FLOOR PANEL 43. REPAIRED PER SRM 53-01, FIG 4. (M)