What was found
MCI - DURING OP 16 MAINTENANCE CHECK, FOUND CORROSION ON GALLEY TIE-DOWN AT STATION 1128 TO STATION 1174, BL 0. REMOVED CORROSION PER SRM 51-10-3, PARA 31-42, AND REPLACED TRACK PER SRM 51-01, 53-14-3, PGE 47. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCI - DURING OP 16 MAINTENANCE CHECK, FOUND CORROSION ON GALLEY TIE-DOWN AT STATION 1128 TO STATION 1174, BL 0. REMOVED CORROSION PER SRM 51-10-3, PARA 31-42, AND REPLACED TRACK PER SRM 51-01, 53-14-3, PGE 47. (M)