What was found
MCI - DURING CHECK-C, MAINTENANCE FOUND AFT END OF LT MLG DOOR HINGE AND ABOVE DOORWAY FRAME SUPPORT BRACE WITH ID CRACKED. REPLACED SUPPORT BRADE PER SRM 51-01, PG 1 ITEM C, AND TWA STD PRACT. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCI - DURING CHECK-C, MAINTENANCE FOUND AFT END OF LT MLG DOOR HINGE AND ABOVE DOORWAY FRAME SUPPORT BRACE WITH ID CRACKED. REPLACED SUPPORT BRADE PER SRM 51-01, PG 1 ITEM C, AND TWA STD PRACT. (X)