What was found
MCI - DURING OP 16 MAINTENANCE CHECK, FOUND STRINGER 29R CORRODED AT TIE CLIP, FS 167. REMOVED CORRODED TIE, ORDERED NEW TIE, DRILLED, DEBURRED, AND INSTALLED NEW TIE PER SRM 51-01, PAGE 1 ITEM C, AND SRM 51-30-2 PAGE 1. TOTAL TIME: 77,783 HOURS. TOTAL CYCLES: 84,471. (X)