What was found
MCI - DURING OP 16 MAINTENANCE CHECK FOUND CORROSION ON NR 1 CHAIR TRACK, STA 1022 TO STA 1041, UNDER AND AROUND SPLICE SCREW HEADS. REPLACED TRACK AND SPLICED REPAIR, STA 1022 TO STA 1136 PER SRM 53-05 FIG 4F, AND SRM 51-01 PAGE 2, PARA C. REF: SERVICE REWORK DRAWING SR0930085. TOTAL TIME: 28,425 HOURS. TOTAL CYCLES: 17,789. (X)