What was found
MCI - DURING OP 16 MAINTENANCE CHECK, FOUND AT STATION 700, LEFT SIDE, BOTTOM AND TOP FORWARD FASTENERS ON INNER STRINGER FRAME THAT HOLDS WINDOW INNER SEAL SPACER RUBBER, CRACKED. INNER FRAME REMOVED AND NEW FRAME INSTALLED PER SRM 51-01, PAGE 1 ITEM C. (M)