What was found
STL - DURING ROUTINE MAINTENANCE, FOUND .50 INCH CRACK AT FASTENER AT STA 794, LONGERON 2R. SPLICED IN NEW SECTION OF LONGERON 20 INCHES LONG PER SRM 53-02, FIG 18. CHECK-C 12-23-97 STL. ACFT TT: 49,615 HOURS. ACFT TC: 45,404. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STL - DURING ROUTINE MAINTENANCE, FOUND .50 INCH CRACK AT FASTENER AT STA 794, LONGERON 2R. SPLICED IN NEW SECTION OF LONGERON 20 INCHES LONG PER SRM 53-02, FIG 18. CHECK-C 12-23-97 STL. ACFT TT: 49,615 HOURS. ACFT TC: 45,404. (X)