What was found
MCI - DURING OP 16 MAINTENANCE CHECK, FOUND ON LT WING 10 INCHES OTBD OF INBD END OF NR 3 SLAT, LE OF WING SPLICE PLATE, CRACKED. REMOVED CRACKED SPLICE PLATE AND INSTALLED NEW PART, DRILLED IN, INSTALLED AD RIVETS AND TENSION HI LOCKS PER SRM 51-30-0 PG 1. ACFT TT: 77,783 HOURS. ACFT TC: 84,471. (X)