What was found
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND LONGERON 4L WITH CRACKED FLANGES AT STA 160. REPLACED LONGERON PER SRM 53-02, PG 48 TO PG 53. REPLACED FASTENERS COMMON TO SKIN USING NAS 1097-6. ACFT TT: 69,860 HOURS. ACFT TC: 81,151. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND LONGERON 4L WITH CRACKED FLANGES AT STA 160. REPLACED LONGERON PER SRM 53-02, PG 48 TO PG 53. REPLACED FASTENERS COMMON TO SKIN USING NAS 1097-6. ACFT TT: 69,860 HOURS. ACFT TC: 81,151. (X)