What was found
DURING OP 16 MAINTENANCE CHECK, FOUND FORWARD CABIN FLOOR PANEL NR 40 WITH HAT SECTIONS CRACKED IN SEVERAL PLACES. REPLACED CRACKED HAT SECTIONS IN FLOOR PANEL NR 40 PER SRM 53-00-104, PAGE 201 FIG 201. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINTENANCE CHECK, FOUND FORWARD CABIN FLOOR PANEL NR 40 WITH HAT SECTIONS CRACKED IN SEVERAL PLACES. REPLACED CRACKED HAT SECTIONS IN FLOOR PANEL NR 40 PER SRM 53-00-104, PAGE 201 FIG 201. (M)