What was found
DURING OP 16 MAINTENANCE CHECK, FOUND LONGERON 24L WITH INNER GRANULAR CORROSION ON ATTACH FITTING AT FWD SIDE OF FS 996. REMOVED CORROSION PER SRM 51-10-03, STEP 35, PAGE 21. ALODINED AND PRIMED PER TWA STD PROCEDURES. INSTALLED NEW ATTACH FITTING PER SRM 51-01. INSTALLED NEW RIVETS PER SRM 51-30-2. ACFT TT: 77,210 HOURS. ACFT TC: 84,221. (X)