What was found
DURING OP 16 MAINT CHECK, FOUND INTERCOASTAL CRACKED AT AFT END OF PULLEY CLUSTER AT STA 1010, RBL 20 INCHES. NEW SUPPORT FABRICATED IN SHOP PER DRAWING 9915540, DRILLED NEW PART AND INSTALLED AND SEALED PER SRM 53-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND INTERCOASTAL CRACKED AT AFT END OF PULLEY CLUSTER AT STA 1010, RBL 20 INCHES. NEW SUPPORT FABRICATED IN SHOP PER DRAWING 9915540, DRILLED NEW PART AND INSTALLED AND SEALED PER SRM 53-03.