What was found
DURING CHECK-C MAINT, FOUND A DENT AT STA 1285 BETWEEN STR 24L AND 25L, RUNNING FROM STR TO STA, 6 IN BY 4 IN BY .070 DEEP. CUT OUT DAMAGED AREA AND INSTALLED EXTERNAL DOUBLER AND FASTENERS PER SRM 53-04 GENERAL FUSELAGE REPAIR FOR PLATING, FIG 12B, CLASS 1 REPAIR.