What was found
DURING CHECK-C, MAINT FOUND RT WING NR 3 TE FLAP, AFT WEDGE LOWER SURFACE HAD 2 IN BY 4 IN DENT LOCATED 26 IN FROM INBD END. FABRICATED 4 IN BY 5 IN PATCH AND INSTALLED PER SRM 51-70-05 AND PAINTED AREA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C, MAINT FOUND RT WING NR 3 TE FLAP, AFT WEDGE LOWER SURFACE HAD 2 IN BY 4 IN DENT LOCATED 26 IN FROM INBD END. FABRICATED 4 IN BY 5 IN PATCH AND INSTALLED PER SRM 51-70-05 AND PAINTED AREA.