What was found
DURING OP 16 MAINT CHECK, FOUND FLOOR PANEL NR 19 WITH CORROSION AND SEVERAL BROKEN SUPPORT CHANNELS. REPLACED CABIN FLOOR PANEL SHEET/HAT SECTION PER SRM 53-00-14, PAGE 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND FLOOR PANEL NR 19 WITH CORROSION AND SEVERAL BROKEN SUPPORT CHANNELS. REPLACED CABIN FLOOR PANEL SHEET/HAT SECTION PER SRM 53-00-14, PAGE 201.