What was found
DURING OP 16 MAINT CHECK, FOUND MEMBRANE BELOW FLOOR AT STA 958, LBL 50 IN, WAS CRACKED. REPAIRED PER SRM 53-01, FIG 2. APPLIED 3 ROWS OF RIVETS ON 0.040 DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND MEMBRANE BELOW FLOOR AT STA 958, LBL 50 IN, WAS CRACKED. REPAIRED PER SRM 53-01, FIG 2. APPLIED 3 ROWS OF RIVETS ON 0.040 DOUBLER.