What was found
DURING OP 16 MAINT CHECK, FOUND FLOOR MEMBRANE CORRODED AT STA 522 TO 541, RT SIDE. REMOVED CORROSION PER STD PROCESSES MANUAL 6-80-1, PARA B PG 1. REPAIRED PER SRM 53-01, PG 18.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND FLOOR MEMBRANE CORRODED AT STA 522 TO 541, RT SIDE. REMOVED CORROSION PER STD PROCESSES MANUAL 6-80-1, PARA B PG 1. REPAIRED PER SRM 53-01, PG 18.