What was found
DURING OP 16 MAINT CHECK, FOUND FLOORBEAM CAP CORRODED AT STA 1156 BETWEEN TRACK LBL 22 AND LBL 42. FABRICATED NEW PART FROM 7075 T6. INSTALLED PER TWA STD PROCESSES MANUAL 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND FLOORBEAM CAP CORRODED AT STA 1156 BETWEEN TRACK LBL 22 AND LBL 42. FABRICATED NEW PART FROM 7075 T6. INSTALLED PER TWA STD PROCESSES MANUAL 6-70-01.