What was found
DURING OP 16 MAINT CHECK, FOUND DENT IN LEADING EDGE OF RT ELEVATOR, APPROXIMATELY 2.25 BY 2.5 INCH AND 0.180 INCH DEEP, LOCATED JUST O/B OF ELEVATOR DAMPER. REPLACED DAMAGED PANEL PER SPM 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND DENT IN LEADING EDGE OF RT ELEVATOR, APPROXIMATELY 2.25 BY 2.5 INCH AND 0.180 INCH DEEP, LOCATED JUST O/B OF ELEVATOR DAMPER. REPLACED DAMAGED PANEL PER SPM 6-70-01.