What was found
DURING OP 16 MAINT CHECK, FOUND SURFACE CORROSION ON FLOORBEAM AT STA 218 TO 237, BL 0. MECHANICALLY REMOVED CORROSION PER TWA STD PROCESS MANUAL. REPAIRED MEMBER PER SRM 53-01, PAGE 10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND SURFACE CORROSION ON FLOORBEAM AT STA 218 TO 237, BL 0. MECHANICALLY REMOVED CORROSION PER TWA STD PROCESS MANUAL. REPAIRED MEMBER PER SRM 53-01, PAGE 10.