What was found
DURING CHECK-C MAINT, FOUND THE LT WING I/B FLAP TRAILING EDGE AFT FLAP BOTTOM SIDE, LOWER WEDGE PANEL WITH A .375 INCH TEAR LOCATED APPROXIMATELY 4 FT O/B BY 11 INCHES HIGH FROM I/B END. REPAIRED PER SRM 51-70-17 (REFERRED FROM SRM 57-53-01) WITH MINIMUM OF 2 PLYS PER NOTE B OF FIG 24, WITH 2 LAYERS OF ADHESIVE TOP AND BOTTOM. COOKED AT 200 DEG, SEALED AND PAINTED.