What was found
DURING OP 15 MAINT CHECK, FOUND LT WING TRAILING EDGE REAR SPAR CENTER UPPER FLAP ATTACH HOLES, I/B AND O/B WITH CRACKS. ACCOMP NDT HIGH FREQ EDDY CURRENT PER SRM 51-00-03, PART 6 CRACK CONTAINMENT. BLENDED AREA PER SRM 57-01, PG 5, FIG 1 SHEET 3. INSTALLED DOUBLERS, FILLERS AND SHIMS PER ARA 16062.