What was found
DURING OP 15 MAINT CHECK, FOUND FLOOR SUPPORT AT STA 160 TO 266, RBL 44 TO 54, WAS CORRODED. FABRICATED NEW SUPPORT, TREATED, PRIMED AND PAINTED PART AND AREA. INSTALLED SUPPORT PER SPM 6-80-01.