What was found
DURING OP 16 MAINT CHECK, FOUND A CRACK IN THE INTERCOSTAL BELOW FLOORBEAM U-CHANNEL AT STA 617. REMOVED AND REPLACED CRACKED INTERCOSTAL PER SPM 6-70-01, PAGE 3, AND USED HI-LOK FASTENERS PER SPM 6-30-07, PAGE 1 AND 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND A CRACK IN THE INTERCOSTAL BELOW FLOORBEAM U-CHANNEL AT STA 617. REMOVED AND REPLACED CRACKED INTERCOSTAL PER SPM 6-70-01, PAGE 3, AND USED HI-LOK FASTENERS PER SPM 6-30-07, PAGE 1 AND 2.