What was found
DURING OP1 6 MAINT CHECK, FOUND WINDOWS 3, 4, AND 5 ON LEFT SIDE OF AIRCRAFT WITH STATIC BURNS. BLENDED EACH PER SRM 53-05 FIG III, AND ARA 16105. INSTALLED EXTERNAL REPAIR ON EACH PER DRAWING SR0950053 AND ARA 16105.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP1 6 MAINT CHECK, FOUND WINDOWS 3, 4, AND 5 ON LEFT SIDE OF AIRCRAFT WITH STATIC BURNS. BLENDED EACH PER SRM 53-05 FIG III, AND ARA 16105. INSTALLED EXTERNAL REPAIR ON EACH PER DRAWING SR0950053 AND ARA 16105.