What was found
DURING CHECK-C MAINT, FOUND THE NR 11 LEADING EDGE SLAT TRAILING EDGE WEDGE WITH DELAMINATION 4.5 INCHES IN DIAMETER, LOCATED 78 IN O/B OF I/B END. INSTALLED METAL TO METAL HOT BOND 6 IN BY 6 IN PER SRM 51-70-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, FOUND THE NR 11 LEADING EDGE SLAT TRAILING EDGE WEDGE WITH DELAMINATION 4.5 INCHES IN DIAMETER, LOCATED 78 IN O/B OF I/B END. INSTALLED METAL TO METAL HOT BOND 6 IN BY 6 IN PER SRM 51-70-10.