What was found
DURING OP 16 MAINT CHECK, FOUND GALLEY FLOOR DRAIN ATTACH ANGLE CORRODED AT BOTTOM OF ANGLE, LOCATED STA 150 TO 160. SANDED AND POLISHED CORRODED ATTACH ANGLE PER SPM 6-80-01, PAGE 1 AND REPLACED ATTACH ANGLE PER SPM 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND GALLEY FLOOR DRAIN ATTACH ANGLE CORRODED AT BOTTOM OF ANGLE, LOCATED STA 150 TO 160. SANDED AND POLISHED CORRODED ATTACH ANGLE PER SPM 6-80-01, PAGE 1 AND REPLACED ATTACH ANGLE PER SPM 6-70-01.