What was found
DURING OP 16 MAINT CHECK, FOUND BELOW ELECTRIC POWER CABLE RACEWAY AT STA 718 APPROX LBL 54 IN, A CRACKED T FITTING. REPLACED FITTING PER SPM 6-70-01 AND INSTALLED HI-LOKS PER SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND BELOW ELECTRIC POWER CABLE RACEWAY AT STA 718 APPROX LBL 54 IN, A CRACKED T FITTING. REPLACED FITTING PER SPM 6-70-01 AND INSTALLED HI-LOKS PER SRM 51-30-5.