What was found
FOUND EXTERIOR EMERGENCY LIGHTS INOPERATIVE AT RT SIDE AND LEFT SIDE NUMBER ONE DOORS, AND THE EGRESS FLOOR STRIP INOPERATIVE AT ROW 27. REPLACED THE BATTERY PACK AND THE BULB AT RT SIDE. BATTERY PACK (P/N 61-0478-3) AND BULB (P/N 1619). EGRESS LIGHT REPOSITIONED FLOOR STRIP AT ROW 27. CHECK-C 6-12-98 MCI.