What was found
A DENT APPEARED TO BE STRAIGHTENED OR PRESSED OUT AT STA 1213, BETWEEN STRINGER 35L AND 36L. ORIGINAL DENT 6 IN BY 3 IN BY .187 DEEP. REPAIRED PER SRM 53-00-01, FIG 201. FOUND DURING OP 16 MAINT CHECK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
A DENT APPEARED TO BE STRAIGHTENED OR PRESSED OUT AT STA 1213, BETWEEN STRINGER 35L AND 36L. ORIGINAL DENT 6 IN BY 3 IN BY .187 DEEP. REPAIRED PER SRM 53-00-01, FIG 201. FOUND DURING OP 16 MAINT CHECK.