What was found
DURING OP 16 MAINT CHECK, FOUND REPAIR ON FLOOR MEMBRANE BETWEEN STA 190 TO 210, LBL O IN TO 22 IN, WAS COMING LOOSE AND HAD POPPED RIVETS INSTALLED. REPLACED MEMBRANE PER SPM 6-70-01, 775T3 30 PER ORIGINAL SAMPLE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND REPAIR ON FLOOR MEMBRANE BETWEEN STA 190 TO 210, LBL O IN TO 22 IN, WAS COMING LOOSE AND HAD POPPED RIVETS INSTALLED. REPLACED MEMBRANE PER SPM 6-70-01, 775T3 30 PER ORIGINAL SAMPLE.